Electric Shock First Aid UK: What to Do, and What Not to Do
What to do when someone gets an electric shock in the UK. The most important rule: do NOT touch the casualty while they are in contact with the source. Get 999 called early, ideally by a bystander on speaker, while you switch off the supply. Call 999 even if they seem fine, and start CPR if they do not respond and are not breathing normally. This guide is not a substitute for practical first aid training.
“Replaced three separate apps with Elec-Mate. Certs, quotes, and scheduling all in one place.”
Key takeaways
01NEVER touch a person who is still in contact with the electrical source, or anything they are touching. You could become a second casualty. Switch off or isolate the supply first.
02Call 999 after any electric shock from an electrical supply, even if the person seems fine. St John Ambulance’s electric shock steps end with that call.
03If the person does not respond, call 999 on speaker straight away, then check their breathing. If it is not normal, including gasping, start CPR and get a defibrillator.
04Household mains is dangerous: HSE says as little as 50 volts across two parts of the body can stop the heart beating properly or stop breathing.
05Any burn caused by electricity needs 999 or A&E, the NHS says, however small it looks. On site, call 999 for a burn caused by electricity.
06Overhead lines and high voltage: never approach. Assume the line is live, keep others away, call 999 and stay back until the line’s owner says it has been made safe.
01 · First Aid Guide
CRITICAL: Do NOT Touch the Casualty While They Are in Contact with the Source
Do NOT touch the casualty if they are still in contact with the electrical source.
A person still touching a live part is part of the circuit. If you touch them, their clothes or anything they are touching, the current can pass through you as well. Then there are two casualties and nobody left to help.
The order that keeps you both alive:
Shout for help and get 999 called: if someone else is there, they call on speaker while you deal with the supply; on your own, call as soon as you safely can
Make the situation safe: switch off or isolate the supply
Only then go to the casualty, once you are sure the contact is broken
This order is not about putting the power before the person. It is the only way to help the casualty without becoming one yourself. HSE’s first-aid leaflet also starts with the same priorities: assess the situation without putting yourself at risk, make the area safe, and send for help without delay. Getting the 999 call started while you make safe is how both happen at once.
Free download · PDF
Get the BS 7671 A4:2026 Cheat Sheet — free
Every key change in the 2026 amendment on one page. AFDDs, TN-C-S protection, new schedule columns, model forms. Pinned on your van dash.
Every regulation change summarised
New model forms (EIC + MEIWC)
Free PDF — no subscription
02 · First Aid Guide
How to Isolate the Electrical Supply
Switching off removes the danger to the casualty and to you. HSE says after a shock the supply must be cut off quickly and help given. The way to do it depends on the situation.
Turn off at the consumer unit: if you can reach it safely without crossing the affected area, turn off the main switch. Anything on the supply side of the main switch, such as the meter and its cables, stays live, so if the person is touching anything there, treat them as still live.
Switch off the appliance at the wall: if the casualty is touching a faulty tool, appliance or lead, switch it off at the socket, without touching the casualty or the damaged equipment. Make sure it is the socket that feeds what they are touching; if you are not sure, treat them as still live.
If you cannot switch off the supply: only for a household or other low-voltage supply, St John Ambulance (voluntary guidance) describes standing on dry insulating material (a wooden box or a plastic mat, for example) and pushing the person’s arm or leg away from the source with a broom handle or wooden pole. If that will not work, loop rope round their arms or ankles and pull them clear. Never touch the person, and never use anything metal or damp.
Overhead lines and high voltage: do not approach. Assume the line or equipment is live, even if it is quiet or looks dead. Keep everyone back, call 999, say power lines are involved, and ask for the line’s owner to be contacted. Stay away until the line’s owner says it has been made safe. No safe distance in metres is given for a rescue.
03 · First Aid Guide
Call 999 for Every Electric Shock
Call 999 for emergency help after any electric shock from an electrical supply, even if the person says they feel fine. St John Ambulance’s electric shock steps end with that call and set no condition on it. For anyone who does not respond, the Resuscitation Council UK says call 999 straight away.
Tell the call handler:
That the person has had an electric shock
Whether they are responding and breathing
Exactly where you are
Whether the supply has been switched off
Any burns or injuries you can see, and any fall
Put the phone on speaker and stay on the line: the call handler can help you check breathing and talk you through CPR while the ambulance is on its way.
If someone else is there: ask one named person to call 999 while you deal with the supply, and another to fetch a defibrillator if there is one nearby.
04 · First Aid Guide
CPR If the Casualty Is Not Breathing Normally
Once the person is clear of the source and it is safe to go near, follow the Resuscitation Council UK 2025 guidelines: check, call, CPR. HSE says an electric shock can stop the heart beating properly.
Check for a response: shout to them and gently shake their shoulders. If there is no response, shout for help.
Call 999 straight away, on speaker, for anyone who does not respond. Since 2025 you no longer wait to confirm their breathing first.
Check their breathing while the call is answered. Slow, laboured breathing or gasping is not normal breathing: it is a sign of cardiac arrest. If in doubt, start CPR. Do not check for a pulse.
Start chest compressions: push hard in the centre of the chest, at least 5 cm but no more than 6 cm deep, 100 to 120 times a minute, which is about twice a second. Let the chest come back up fully each time.
Rescue breaths only if trained: if you have been trained, give 30 compressions then 2 breaths. If you have not, keep giving compressions without stopping. The call handler will guide you.
Use a defibrillator (AED) as soon as one arrives: switch it on and follow its prompts. Anyone can use one, and it will only allow a shock if one is needed. Make sure nobody touches the person during analysis or the shock. It can usually be used on a wet floor as long as nobody is touching the person when the shock is given; dry a wet chest so the pads stick.
Keep going until the ambulance crew takes over, the person starts to show signs of life, such as breathing normally or moving with purpose, or you are too exhausted to carry on.
05 · First Aid Guide
Low Voltage vs High Voltage: What Changes
Low voltage does not mean low risk. What changes with high voltage is how you can help: with low voltage you switch off and then help; with high voltage you stay back.
Low voltage: includes household mains (230V)
HSE says as little as 50 volts across two parts of the body can stop the heart beating properly, stop breathing or cause muscle spasms. How bad a shock is depends on things such as the voltage, where the current passes through the body, how wet the person is and how long it lasts. Spasms can stop the person letting go. A domestic supply can cause deep burns if the current flows for more than a split second.
High voltage: overhead lines and high-voltage equipment
HSE’s guidance HSG85 defines high voltage as more than 1000 V AC or 1500 V DC. HSE says high voltage can arc across an air gap, so you can be shocked or burned without touching anything live. Arcing can cause deep, slow-healing burns and its ultraviolet light can damage the eyes. Never approach: keep others back, call 999 and, for an overhead line, stay away until the line’s owner says it has been made safe. Many low-voltage overhead lines have bare wires too, so treat every overhead line the same way.
In the app
Try Elec-Mate free for 7 days
19 certificate types, 70+ calculators, RAMS, quoting, invoicing, AI agents, and 46+ training courses — from £6.99/mo.
06 · First Aid Guide
After the Shock: Burns, Falls and Getting Help
Once the person is clear and 999 has been called, look for burns and for injuries from any fall, and keep watching their breathing until help arrives.
Any electrical burn needs 999 or A&E, the NHS says. Hold it under cool running water for 20 minutes, as soon as you can. Take off clothing or jewellery near it unless stuck to the burn, then lay cling film over it without wrapping it round. No creams, oils, butter or plasters, and do not burst blisters.
Cooling must not delay hospital: HSE’s first-aid leaflet makes this point, and St John Ambulance and the British Red Cross (voluntary guidance) warn against cooling so much of the body that the person gets too cold.
Think about a fall: HSE says a shock can throw a person off a ladder or into nearby machinery. After a fall from height, the Resuscitation Council UK says do not put the person in the recovery position. Keep the neck as still as you can, never force them into a position, and remember that opening the airway always comes first. Tell the call handler about the fall.
Spasms can break bones: HSE says the muscle spasms from a shock can be violent enough to break bones or dislocate joints.
Do not let the casualty drive themselves: the NHS says not to drive yourself to A&E. A burn from current means they have had a shock, so call 999 and wait for the ambulance.
07 · First Aid Guide
Why a Shock Can Look Minor When It Is Not
People often shake off a shock and say they are fine. How someone looks straight afterwards is not a safe guide, and that is why this guide says call 999 after every shock from an electrical supply.
Burns can be deep: HSE explains that current heats the tissue all along its path, and the burns that result can be deep, often need major surgery and can be permanently disabling. The mark on the skin tells you nothing about what lies underneath.
You cannot tell in advance: HSE’s guidance HSG85 says a shock does not always cause lasting injury, but in some circumstances it can kill. Nobody at the scene can tell which.
Keep watching while you wait: if the person stops responding, or their breathing becomes slow, laboured or gasping, treat it as cardiac arrest: make sure 999 knows and start CPR. A short burst of jerking at collapse can be the start of a cardiac arrest; once it stops, check their breathing.
Stay with the person until help arrives. If you are not sure whether something is serious, the 999 call handler can advise you.
08 · First Aid Guide
Prevention: Reducing the Risk of Electric Shock
The best electric shock first aid is never needing it. St John Ambulance says shocks are generally caused by loose or faulty switches, faulty appliances and worn flexes, and handling electrical items with wet hands.
Test your RCDs regularly: HSE says an RCD rated at no more than 30mA can save your life, though it cannot protect against every type of shock. Press the test button and check that it trips, as often as the notice beside it says. See our home electrical safety guide for full testing instructions.
Use RCD protection for power tools: HSE advises using an RCD wherever possible, particularly outdoors and in damp places. A plug-in RCD only protects what is plugged into it. See our guide on extension lead safety.
Stop using damaged leads and appliances: HSE says equipment should be checked by eye for early signs of damage. Take anything damaged out of use until it has been repaired or replaced.
Have your installation inspected periodically: an Electrical Installation Condition Report (EICR) by a competent electrician can find faults before they cause harm. HSE says installations should be tested often enough that they are unlikely to become dangerous between tests.
Learn CPR: the Resuscitation Council UK says everyone can learn how to do CPR. A practical, hands-on first aid course is the way to learn and practise it.
In the app
Are you an electrician? Help keep UK homes electrically safe
Elec-Mate helps UK electricians with on-site EICR completion, AI board scanning, and instant PDF export. Start your 7-day free trial.
Elec-Mate is my go to app for business and electrical work. It's feature rich without feeling cluttered. A true all in one app for quotes, certs, calculations, RAMS, EICRs, and more. I use it every day without fail, and it makes my workflow much smoother since I'm not jumping between apps anymore. The price-to-feature ratio is excellent. Any issues I've had, the developer responds within the hour and usually fixes them the same day. 100% recommend.
Fantastic app for electricians
I've used the app and the web based version for a while now and it's well worth the investment. If you're an apprentice or experienced Spark give it a go, you won't be disappointed.
Absolutely amazing
I've been using Elec-Mate for a while now, and honestly, it's one of the best apps I've ever downloaded. Every aspect of it feels thoughtfully designed, from the clean and intuitive interface to the powerful features that make everything so easy to manage. It's clear that a lot of care and attention went into building this app, and it shows in every detail.
Trusted by electricians across the UK
Real feedback from electricians and apprentices
“Replaced three separate apps with Elec-Mate. Certs, quotes, and scheduling all in one place.”
Daniel Palmer
Sole Trader · DP Electrical
“I've won two contracts this month because I could turn quotes around same-day with the AI cost engineer.”
Nathan Perry
Electrician · NP Electrical Services
“The study centre got me through my AM2. Mock exams and flashcards are brilliant.”
Jake Pizey
3rd Year Apprentice · Apprentice
7-day free trial
Are You an Electrician? Complete EICRs Faster with Elec-Mate
Join 2,830+ UK electricians on Elec-Mate. Elec-Mate is built for UK electricians: on-site EICR completion, AI board scanning, and instant PDF export. 7-day free trial, cancel anytime.