Free mock exam

Standards and design — Fibre Optics Practice

Free topic-focused mock exam: all 30 questions on Standards and design, drawn from the wider Fibre Optics bank. 35-minute timer, 70% to pass, worked explanation on every question. Use this when you've taken the full mock once and want to drill the topics you got wrong.

Questions
30
Time limit
35 min
Pass mark
70% · 21/30
Question bank
30

Free, no sign-up. Retake as many times as you like — the questions are reshuffled, with the answer order changed.

Sample questions

  1. 01A loose-tube fibre cable will run in external duct between two buildings. Which part of the BS EN 50174 series covers cabling outside buildings?
    • ABS EN 50310
    • BBS EN 50174-2
    • CBS EN 50174-1
    • DBS EN 50174-3

    Why: BS EN 50174-3 deals with cabling outside buildings. BS EN 50174-2 is tempting because it is the part named most often, but it covers planning and practice inside buildings. BS EN 50174-1 is the installation specification and quality assurance, and BS EN 50310 is the bonding standard.

  2. 02A facilities manager wants a rule for how the cabling and its containment are documented and labelled, and how moves and changes are recorded. Which standard defines that administration?
    • AISO/IEC 11801-1
    • BIEC 60825-1:2014
    • CIEC 61280-4-2
    • DIEC 61300-3-35

    Why: ISO/IEC 11801-1 defines administration: documenting the cabling and its containment, labelling its parts and recording moves, additions and changes. IEC 61300-3-35 is tempting because it also deals with records of a sort, but it only covers end-face inspection. IEC 61280-4-2 is a loss test method and IEC 60825-1:2014 classifies laser products.

  3. 03The client’s new multimode backbone uses bend-insensitive multimode fibre. Which test standard’s current edition added that fibre to its scope?
    • AIEC 61300-3-35 Ed. 3
    • BIEC 61280-4-1 Ed. 3
    • CIEC 61280-4-2 Ed. 2
    • DISO/IEC 14763-3:2014

    Why: IEC 61280-4-1 Ed. 3 (2019) is the attenuation method for installed multimode cabling, and that edition added bend-insensitive multimode fibre. IEC 61280-4-2 is tempting as it is the same family, but it is the singlemode method. ISO/IEC 14763-3 refers to those methods rather than defining them, and IEC 61300-3-35 is end-face inspection.

Common questions

Is the Standards and design mock exam free?

Yes, it is free with no sign-up needed. Questions are pulled at random from a substantial bank, with a worked explanation on every question after you submit.

Can I retake the mock exam?

Yes. Every attempt picks a different random selection and reshuffles the options, so each retake gives you genuinely new questions. No limit on retakes.

Does this count as a qualification?

No. This is independent practice material and does not award a qualification, card or certificate. Where a subject has a formal qualification or card, you gain it through an approved provider.

Certificate types
19Certificate types
Calculators
70+Calculators
Training courses
46+Training courses
AI specialists
8AI specialists