Safety Training

First aid awareness for electricians

First aid awareness for UK electricians: the law, the needs assessment, electric shock, keeping someone alive until help arrives, and burns, bleeding and injuries on site. 5 modules, 20 lessons and a 20-question mock exam from a 150-question bank, with quizzes and an AI study assistant. Awareness only: not Emergency First Aid at Work or First Aid at Work training, and no first-aid certificate.

Free for 7 days · No charge until day 8 · Cancel anytime · Used by 2,600+ UK electricians

10 min readUpdated 2026-10-29Andrew Moore, Founder of Elec-Mate
ShareXinW
Follow

2,600+

UK electricians

“Replaced three separate apps with Elec-Mate. Certs, quotes, and scheduling all in one place.”

Daniel Palmer, DP Electrical · 5 out of 5

Course Overview

Duration
About 9 hours
Level
Beginner
Prerequisites
None: suitable for all electricians and apprentices
Modules
6 modules
Certification
No certificate or card. An awareness course, not EFAW or FAW training or a first-aid qualification, and it does not make you a first-aider; you can record the study time as CPD

Who Is This For?

Electricians, electrical apprentices and site supervisors who want to know what the first-aid law asks for and what to do until help arrives, above all after an electric shock

Key takeaways

  1. 01After an electric shock, never touch someone who is still in contact with the supply. Switch off or isolate first. At an overhead line or near high voltage, stay back and keep others back until the line’s owner says it has been made safe.
  2. 02If someone does not respond, the Resuscitation Council UK (2025) says call 999 straight away, on speaker, and then check their breathing. Gasping is not normal breathing. Start CPR: 30 compressions to 2 breaths only if you are trained in rescue breaths, otherwise continuous compressions.
  3. 03The NHS says any burn caused by electricity needs 999 or A&E, however small it looks. On site, call 999: a burn from current means a shock. HSE explains why: current heats the tissue all along its path, so the burn can be deep.
  4. 04The First-Aid Regulations 1981 put a duty on employers to provide first-aid equipment, facilities and people that are adequate and appropriate. HSE has not approved first-aid training since October 2013, except for some offshore roles.
  5. 05This course is awareness only. It is not Emergency First Aid at Work or First Aid at Work training, it gives no first-aid certificate, and it does not make anyone a first-aider.

Why First Aid Awareness Matters for Electricians

HSE’s first-aid guidance (L74) lists electricity among the workplace hazards a first-aid needs assessment should consider, with electric shock, burns and heart attack as the injuries it can cause. Work at height brings head injuries, loss of consciousness, spinal injuries and fractures. Electricians meet both.

The law defines first aid, where a doctor or nurse will be needed, as treatment to preserve life and limit the harm until that help arrives. After an electric shock the person nearest is usually a workmate, so knowing what to do in the first minutes, and what not to do, matters. HSE says as little as 50 volts across two parts of the body can drive a current that stops the heart beating properly or stops breathing.

The safe isolation procedure is the main defence against electric shock. This course covers what to do when something still goes wrong: making the scene safe, getting 999 called, CPR and the defibrillator, and burns, bleeding and falls. It is an awareness course. It is not Emergency First Aid at Work or First Aid at Work training, it gives no first-aid certificate, and it does not replace practical training.

Electric Shock Response

The first priority is your own safety. A person who is still in contact with a live part is part of the circuit, and touching them, their clothes or anything they are touching can put the current through you too. Shout for help so someone can call 999 while you deal with the supply.

Switch off or isolate the supply first. HSE’s guidance on live work says after a shock the supply must be cut off quickly and help given. Make sure the switch you use actually feeds what the person is touching; if you are not sure, treat them as still live. Only at low voltage, and only if you cannot switch off, St John Ambulance (voluntary guidance, not law) describes standing on dry insulating material (a wooden box or a plastic mat, for example) and pushing the limb clear with a broom handle or wooden pole, or looping rope round the arms or ankles, without touching the person.

Overhead lines and high voltage are different. Never touch the wires, and assume they are live even if they are quiet or look dead: HSE’s GS6 says lines can be switched back on automatically or remotely. Keep away, keep others away, call 999, say power lines are involved, and ask for the line’s owner to be contacted. Stay away until the line’s owner says it has been made safe. No distance in metres is given for a rescue. Near exposed high-voltage equipment, do not approach at all: high voltage can arc through the air.

Once the person is clear of the supply, check whether they respond. If they do not, make sure 999 has been called, then check their breathing and start CPR if it is not normal. Even if they seem fine, call 999 for emergency help: St John Ambulance’s electric shock steps end with that call. Any burn caused by electricity needs 999 or A&E, the NHS says; on site, call 999 for a burn caused by electricity. For the paperwork side of electrical work, see our guide to electrical certificate types.

In the app

Work through electric shock scenarios

Module 3 takes you through what to do at low voltage, at overhead lines and near high voltage, and once the person is clear, with a site scenario and quiz in every lesson.

CPR and AED Use

HSE says an electric shock can stop the heart beating properly. The Resuscitation Council UK (RCUK) 2025 guidelines put it as check, call, CPR. Check that it is safe to approach and whether the person responds. If they do not, call 999 straight away, on speaker, and then check their breathing while the call is answered. Since 2025 you no longer wait to confirm abnormal breathing before calling. Slow, gasping or laboured breathing is a sign of cardiac arrest, and if you are in any doubt, start CPR. There is no pulse check for lay rescuers.

Push hard in the centre of the chest, at least 5 cm but no more than 6 cm deep, 100 to 120 times a minute: about twice a second. If you have been trained in rescue breaths, give 30 compressions then 2 breaths. If you have not, keep giving chest compressions without stopping. The 999 call handler will talk you through it.

RCUK says anyone can use an automated external defibrillator (AED). Switch it on and follow its prompts; it will only allow a shock if one is needed. Make sure nobody touches the person during analysis or the shock. RCUK says an AED can usually be used safely on a wet or metal surface as long as nobody is in contact with the person when the shock is given; dry a wet chest so the pads stick. HSE says the law does not require a workplace to have an AED.

In the app

Practise with unlimited mock exams

AI-generated mocks, instant marking, and explanations on every question — targeted at your weakest topics. From £6.99/mo.

Burns Treatment for Electrical Injuries

HSE explains that current passing through the body heats the tissue all along its path, which can cause deep burns that often need major surgery. A domestic supply can do this too if the current flows for more than a split second. So the mark on the skin is no guide to how bad the burn is underneath.

Arcing is a separate danger. HSE’s HSG85 says an arc can cause deep-seated, slow-healing burns even if it is brief, and its intense ultraviolet light can damage the eyes. Stopping the arc happening in the first place matters more than any first aid; see our guide to PPE for electricians.

The NHS says call 999 or go to A&E for any burn caused by electricity, as well as burns that are very large or deep. On site, call 999: a burn from current means a shock. While help is on its way, hold the burn under cool running water for 20 minutes, as soon as possible. Take off clothing or jewellery near the burn, but leave anything that is stuck to it. Once it is cooled, lay cling film over it without wrapping it round. No creams, oils or butter, no plasters, and do not burst blisters. Cooling must not hold up getting the person to hospital, and do not let the casualty drive themselves.

Workplace Emergencies and Reporting

Beyond electric shock, the course covers what you may meet on site while help is on its way: someone unresponsive after a fall, choking, chest pain, stroke and seizures, severe bleeding and needlesticks, chemical burns and eye injuries, broken bones, and heat and cold. After a fall from height, RCUK says not to put the person in the recovery position: keep the neck as still as you can, but opening the airway always comes first.

The Reporting of Injuries, Diseases and Dangerous Occurrences Regulations (RIDDOR) 2013 require the responsible person, for an employee usually the employer, to report certain incidents. These include deaths; specified injuries to workers, such as a fracture other than to a finger, thumb or toe, a burn covering more than 10% of the body or seriously damaging the eyes, breathing or other vital organs, or loss of consciousness caused by a head injury or asphyxia; injuries keeping someone off normal work for more than seven days in a row; and dangerous occurrences, such as plant or equipment accidentally touching an uninsulated overhead line above 200 volts. An electric shock is not on its own a specified injury, so not every shock is reportable, but it is good practice to record every shock.

Employers must tell employees about the first-aid arrangements, including where the kit, facilities and people are. HSE suggests at least one notice in a prominent place at each site, and HSE’s construction guidance says site inductions should cover first-aid arrangements.

Course Modules

1

First aid at work: the law

What this course is and is not, the employer’s first-aid duty, self-employed and shared sites, and records and RIDDOR.

2

Needs assessment, people, kit and support

The needs assessment, appointed persons and first-aiders, kits and defibrillators, and looking after yourself afterwards.

3

Electric shock: make it safe, then help

What electricity does to the body, not becoming the second casualty, overhead lines and high voltage, and care once the person is clear.

4

Keeping someone alive until help arrives

Check, call and CPR, using a defibrillator, unresponsive casualties and falls, and choking, chest pain, stroke and seizures.

5

Burns, bleeding and injuries on site

Thermal and electrical burns, chemical burns and eyes, severe bleeding and needlesticks, and shock, fractures, heat and cold.

6

Mock exam

20 questions drawn from a 150-question bank across all five modules, 30 minutes, 80% to pass.

What You Get With Elec-Mate

AI Study Assistant

Ask any question about the course in plain English while you study: the First-Aid Regulations, the needs assessment, electric shock, CPR or reporting under RIDDOR.

Site Scenarios

Every lesson includes a site scenario, such as a colleague locked onto a live terminal or a tipper touching a farm line, with what to do and why it matters.

Interactive Quizzes

Quick checks inside every lesson and a quiz at the end of each one, on electric shock, CPR and the defibrillator, burns, bleeding and reporting.

Short Lessons

20 lessons of about 25 minutes each, so you can study at your own pace on a phone, tablet or computer.

Flashcard Decks

Spaced repetition flashcards for quick recall of health and safety facts, including first aid.

Mock Exam

20 questions drawn from a 150-question bank across all five modules, 30 minutes, 80% to pass. Every answer explains the rule and where it comes from.

Frequently Asked Questions

Trusted by electricians across the UK

Real feedback from electricians and apprentices

“Replaced three separate apps with Elec-Mate. Certs, quotes, and scheduling all in one place.”

Daniel Palmer

Sole Trader · DP Electrical

“I've won two contracts this month because I could turn quotes around same-day with the AI cost engineer.”

Nathan Perry

Electrician · NP Electrical Services

“The study centre got me through my AM2. Mock exams and flashcards are brilliant.”

Jake Pizey

3rd Year Apprentice · Apprentice

7-day free trial

Ready to learn what to do until help arrives?

Join 2,830+ UK electricians on Elec-Mate. First aid awareness built for UK electricians: 5 focused modules on the law, electric shock, CPR and the defibrillator, burns, bleeding and site injuries, with checks in every lesson and a mock exam. 7-day free trial, cancel anytime.

Start your free trial

From £6.99/mo after the trial — no charge until day 8.

“Replaced three separate apps with Elec-Mate. Certs, quotes, and scheduling all in one place.”

Daniel Palmer, DP Electrical · 5 out of 5
  • 7 days free, then from £6.99/mo
  • Cancel in one tap — no calls, no hassle
  • iOS, Android and web
  • Built to BS 7671:2018+A4:2026

Or download the app

Download on the App StoreGet it on Google Play
Certificate types
19Certificate types
Calculators
70+Calculators
Training courses
46+Training courses
AI specialists
8AI specialists